EXPERTS IN LOUVRE SYSTEMS & BRISE SOLEIL

Friday, 11 February 2011

Automated Louvres

Nationwide Louvre Company save the bells


Nationwide Louvre Company designed, manufactured and installed double bank weather louvres with motorised heavy duty shut off dampers to the bell tower at Dublin Cathedral.


The double bank louvres reduced the possibility of water ingress, but due to the very exposed location of the louvres, heavy duty shut off damper with a closure rate of 99.9% shut off were fitted.
The dampers were fitted with fail safe (spring return) actuators that allowed each of the elevations to be opened or closed separately.


This was of particular interest to the architect (Mr John Baumont), as the Cathedral were able to close off the louvres whilst bell ringing practice took place reducing the effect the bells had on local residents during the week.

Wednesday, 2 February 2011

Monday, 31 January 2011

Naturalvent combined with Solar Shading

There are a number of ways to create natural ventilation in a building. One of the most basic is probably also one of the most effective: create windows which open to generate wind driven ventilation. By opening and closing windows, people can control the flow of air through a structure, opening more windows to encourage fresh air, which can cool a structure in addition to carrying away smells, and closing windows to generate less of a flow of air, keeping a structure warmer.
Stack ventilation is another natural ventilation option. With stack ventilation, people rely on natural pressure differences between air in various locations to force air up ventilation stacks. This technique is often used in factories, where tremendous amounts of heat can be generated by machinery and manufacturing processes, with the warm air being pulled up the stacks along with odors from the factory floor.
Stack ventilation is usually facilitated with the use of controllable intake vents / louvres which are located low to the ground, generating a steady flow of fresh, cool air.
One of the biggest advantages of natural ventilation is that it does not cost large amounts of money to run. Mechanical ventilation and electronic climate control can be very costly, and may contribute significantly to the overall energy usage and carbon footprint involved with running a building.
Natural Ventilation with controllable weather louvres and (NLC) Roofavent wind terminals can be a sensible way of working with traditional low energy mechanical ventilation systems to ensure the perfect building environment.
The inclusion of a well designed Brise Soleil / Solar Shading system can help reduce solar gains through large glazed areas by up to 80% in the summer months. This will not only reduce cooling loads but reduce the sensation of over heating caused by the sun on the occupants skin.

For more information contact NLC or visit the web site.





.

Acoustic Louvres

Friday, 28 January 2011

Louvre Screen

Louvre Screen

Naturalvent Limited not just Naturalvent.

Solar Shading

Solar Shading

Naturalvent Limited not just Naturalvent.

Thursday, 27 January 2011

Wednesday, 26 January 2011